◆ microprocessor logic control, dds type sine wave generation, bipolar full-bridge spwm inverter; pure output waveform。
◆ wide ac input range, input voltage fluctuation range ±30%. input and output are completely isolated。
◆ an lc peak voltage filter is added to the input, which can filter out the peak voltage below 600v of the grid。
◆ the two outputs are isolated from each other, and the inverter control is isolated, without the need for an isolation transformer at the output end。
◆adopt active soft switch power factor correction to make the input power factor reach 0.99。
◆ lcd and led dual display, clearly understand the various conditions and parameters of the power supply。
◆ this machine has a fault self-test function, which can automatically detect, process and alarm for faults。
◆ when the input is switched between two channels, the module can provide a continuous flow time of 150 milliseconds。
◆ the switching time of dual-system hot backup is less than 25 milliseconds。
◆ modules can be used in hot backup in parallel, and switch automatically within 25 milliseconds after failure。
◆ meet the electromagnetic compatibility tb/t3073-2003, class a requirements。
◆ the design of the power supply screen complies with the railway standard tb/t1528.1-2002 "railway signal power supply screen part i general provisions", tb/t1528.7-2002 "railway signal power supply screen part 7: 25hz signal power supply screen"。
if the following requirements fail to meet your parameter requirements, you can call to customize!
model
|
alc25-2000
|
alc25-4000
|
capacity
|
2kw
|
4kw
|
enter
|
input rated voltage
|
ac220v (rail, local sharing), 50hz
|
input voltage range
|
input ±25% of rated voltage
|
input frequency range
|
47~63 hz
|
input power factor
|
≥0.99
|
output
|
the output voltage
|
track
|
ac220v ±6.6v
|
ac220v ±6.6v
|
partial
|
ac110v±3.3v
|
ac110v±3.3v
|
output current
|
track
|
5.5a
|
10.9a
|
partial
|
7.3a
|
14.5a
|
output power
|
track
|
1200w@220v
|
2400w@220v
|
partial
|
800w@110v
|
1600w@110v
|
output frequency
|
25hz±0.4%
|
phase
|
the output voltage phases of the two main and standby modules are synchronized, and the local power phase is 90° ahead of the track power
|
phase angle accuracy
|
≤±3 degrees
|
total harmonic content
|
≤3%
|
dynamicvoltageresponse
|
overshoot ≤10% (when load changes from 0-50-100%), stabilization time ≤0.2 seconds
|
deviceoverloadcapacity
|
110% for 10 minutes; 150% for 10 seconds
|
dc component
|
output dc component ≤ 1v
|
displayfunction
|
power, fault, power supply led indication
|
overallefficiency(fullload)
|
η≥88%
|
protect
|
output short circuit protection
|
after the power output is short-circuited, stop the output
|
output overcurrent protection
|
when the host is running, the output load is 110%, the module is protected, the fault light is on, and it switches to the standby machine to work
|
input undervoltage protection
|
the input voltage is reduced to 155±5vac, the fault light is on, and it switches to standby operation
|
input overvoltage protection
|
the input voltage is boosted to 285±5vac, the fault light is on, and it switches to standby operation
|
output undervoltage protection
|
200vac±5v, protect and switch to standby machine
|
whole machine overheating protection
|
air cooling, load control fan speed regulation, protection when the internal temperature is greater than 85℃
|
conversion method
|
active/standby conversion. when any module fails, it should be able to automatically switch to the standby module, and unplug any module.
|
two-machine switching time
|
when one module is used, the other module should be able to work normally.
|
electromagnetic compatibility
|
less than 25 milliseconds
|
machine noise
|
the tb/t 3073-2003 standard meets the requirements of the tb/t 3073 2003 standard in the railway industry.
|
other
|
≤60db
|
dielectric strength
|
insulationresistance
|
≥100mω
|
dielectric strength
|
ac2000v 10ma 1min
|
mtbf
|
≥100000h
|
dimensions
|
1/2模块(310×343×445mm)
|
working environment
|
storage temperature
|
-30℃~ 55℃
|
operatingtemperature
|
-10℃~ 50℃
|
relative humidity
|
≤90%
|
atmosphericpressure
|
106-74.8kpa (under 2500 meters above sea level)
|
interface definition
|
meet the standards of the ministry of railways
|