◆ made of stainless steel alloy resistors。
◆ the discharge power can be set according to the power detection requirements, and can be put in a combination of buttons。
◆ detect the working efficiency of various power generation equipment and discharge equipment, the maximum output power and load capacity of full load operation。
◆ simulate various complex working environments, sudden increase and unload of power, and detect the actual loading capacity and efficiency of the discharge equipment。
◆ the use of precise and high-precision load materials can truly simulate the actual load's loading force and the ability to adapt to slight changes in the load。
◆ emergency stop and temperature protection, overload, short circuit, over-temperature equipment automatically cut off。
◆ upper limit and lower limit voltage setting, automatically drop to the range voltage point according to the energy (limited program control machine)。
◆ temperature protection setting, temperature 0~100° can be set, and real-time temperature condition can be detected at the same time。
◆ programmable interface 0~30 groups of power and current can be set arbitrarily, the minimum execution time is 1ms and can be cycled 999999 times (limited to program-controlled machine)。
◆ the minimum resolution of the load is 1w, which can accurately simulate the power generation or on-off capability of the product。
◆ it is possible to upload the measurement data to the computer and realize the process record and storage function of the detection process data (only programmable controller)。
◆ there are two operation modes: panel operation or remote control (program-controlled machine only)。
◆ with over-temperature protection function, temperature setting and temperature monitoring。
◆ different time constant loads can be customized。
◆ used in generators, ups, switches, fuses, electrical accessories, transformers, temperature rise tests, low-voltage electrical factory inspection, production debugging, simulation of harsh loads,accurate testing sites for environment, scientific research and development, military industry, etc。
◆ use button control or switch switch (touch screen control with rs232 communication interface)。
◆ can measure voltage, current, power。
charging pile / electricity/communication / telecom / netcom/mobile / unicom / tietong / civil aviation / inverter / dc generator set / auto 4s shop battery maintenance test maintenance and other industries.
dlb-lr dc group load (including program control)
|
product name
|
12v vehicle power supply test load
|
24v dc power supply test load
|
28v aviation power test load
|
48v dc screen test load
|
220v dc switching power supply discharge load
|
500v charger test load
|
special test load for 600v ground power locomotive
|
model number
|
dlb-lr series
|
main technical indicators of load box
|
the specific voltage value and power value can be customized according to user needs
|
rated voltage
|
dc 12v
|
dc 24v
|
dc 28v
|
dc 48v
|
dc 220v
|
dc 380v
|
dc 600v
|
rated power
|
5kw
|
12kw
|
14kw
|
24kw
|
22kw
|
190kw
|
300kw
|
load nature
|
purely resistive
|
purely resistive
|
purely resistive
|
purely resistive
|
purely resistive
|
purely resistive
|
purely resistive
|
control method
|
dc circuit breaker
|
dc circuit breaker
|
dc circuit breaker
|
dc circuit breaker
|
dc circuit breaker
|
dc contactor
|
dc contactor
|
electriccurrentsegmented
|
5a-180a
|
1a-500a
|
1a-500a
|
1a-500a
|
1a-100a
|
1a-400a
|
1a-500a
|
voltage accuracy
|
0.50%
|
0.50%
|
0.50%
|
0.50%
|
0.50%
|
0.50%
|
0.50%
|
voltage resolution
|
0.1v
|
0.1v
|
0.1v
|
0.1v
|
0.1v
|
0.1v
|
0.1v
|
adjustmentaccuracy
|
±5%
|
±5%
|
±5%
|
±5%
|
±5%
|
±5%
|
±5%
|
the meter shows
|
无
|
led digital ammeter, voltmeter (other meters are optional)
|
led digital ammeter, voltmeter (other meters are optional)
|
led digital ammeter, voltmeter (other meters are optional)
|
led digital ammeter, voltmeter (other meters are optional)
|
led digital ammeter, voltmeter (other meters are optional)
|
led digital ammeter, voltmeter (other meters are optional)
|
load protection
|
overcurrent protection, high temperature alarm, fan failure alarm (optional)
|
overcurrent protection, high temperature alarm, fan failure alarm (optional)
|
overcurrent protection, high temperature alarm, fan failure alarm (optional)
|
overcurrent protection, overvoltage protection, high temperature alarm, fan failure alarm (optional)
|
overcurrent protection, overvoltage protection, high temperature alarm, fan failure alarm (optional)
|
overcurrent protection, overvoltage protection, high temperature alarm, fan failure alarm (optional)
|
overcurrent protection, overvoltage protection, high temperature alarm, fan failure alarm (optional)
|
cooling method
|
forced air cooling
|
forced air cooling
|
forced air cooling
|
forced air cooling
|
forced air cooling
|
forced air cooling
|
forced air cooling
|
size w*l*h
|
480*650*600mm
|
480*650*600mm
|
480*800*820mm
|
600*900*1000mm
|
600*900*1000mm
|
1200*950*1600mm
|
1100*1450*1700mm
|
optionalfunction
|
/
|
/
|
computer remote monitoring
|
computer remote monitoring
|
computer remote monitoring
|
computer remote monitoring
|
computer remote monitoring
|
|
|
|
|
|
touch screen control
|
touch screen control
|
touch screen control
|
touch screen control
|
touch screen control
|
|
|
|
|
|
report printing
|
report printing
|
report printing
|
report printing
|
report printing
|
接下表:
product name
|
32v battery discharge test load
|
48v battery discharge test load
|
750v charging pile test load
|
800v charging pile test load
|
1000v charging pile test load
|
750v charging pile test load
|
750v charging pile test load
|
model number
|
dlb-lr series
|
main technical indicators of load box
|
the specific voltage value and power value can be customized according to user needs
|
model number
|
dlb-lr5/32
|
dlb-lr120/48
|
dlb-lr60/075
|
dlb-lr60/08
|
dlb-lr120/010
|
dlb-lr200/07-5
|
dlb-lr300/07-5
|
rated voltage
|
dc 32v
|
dc48v
|
dc 750v
|
dc 800v
|
dc 1000v
|
dc 750v
|
dc750v
|
rated power
|
5kw
|
120kw
|
60kw
|
60kw
|
120kw
|
200kw
|
300kw
|
load nature
|
purely resistive
|
purely resistive
|
purely resistive
|
purely resistive
|
purely resistive
|
purely resistive
|
purely resistive
|
control method
|
dc circuit breaker
|
dc circuit breaker
|
dc circuit breaker
|
dc circuit breaker
|
dc circuit breaker
|
dc contactor
|
dc contactor
|
electriccurrentsegmented
|
1a-160a
|
1a-250a
|
1a-80a
|
1a-75a
|
1a-120a
|
1a-267a
|
1a-400a
|
voltage accuracy
|
0.50%
|
0.50%
|
0.50%
|
0.50%
|
0.50%
|
0.50%
|
0.50%
|
voltage resolution
|
0.1v
|
0.1v
|
0.1v
|
0.1v
|
0.1v
|
0.1v
|
0.1v
|
adjustment accuracy
|
±5%
|
±5%
|
±5%
|
±5%
|
±5%
|
±5%
|
±5%
|
the meter shows
|
led digital ammeter, voltmeter (other meters are optional)
|
led digital ammeter, voltmeter (other meters are optional)
|
led digital ammeter, voltmeter (other meters are optional)
|
led digital ammeter, voltmeter (other meters are optional)
|
led digital ammeter, voltmeter (other meters are optional)
|
led digital ammeter, voltmeter (other meters are optional)
|
led digital ammeter, voltmeter (other meters are optional)
|
load protection
|
overcurrent protection, high temperature alarm, fan failure alarm (optional)
|
overcurrent protection, high temperature alarm, fan failure alarm (optional)
|
overcurrent protection, high temperature alarm, fan failure alarm (optional)
|
overcurrent protection, overvoltage protection, high temperature alarm, fan failure alarm (optional)
|
overcurrent protection, overvoltage protection, high temperature alarm, fan failure alarm (optional)
|
overcurrent protection, overvoltage protection, high temperature alarm, fan failure alarm (optional)
|
overcurrent protection, overvoltage protection, high temperature alarm, fan failure alarm (optional)
|
heatdissipationmethod
|
forced air cooling
|
forced air cooling
|
forced air cooling
|
forced air cooling
|
forced air cooling
|
forced air cooling
|
forced air cooling
|
size w*l*h
|
480*650*600mm
|
940*950*1500mm
|
650*900*1200mm
|
650*900*1200mm
|
940*950*1500mm
|
1200*950*1600mm
|
1100*1450*1700mm
|
optionalfunction
|
/
|
/
|
computer remote monitoring
|
computer remote monitoring
|
computer remote monitoring
|
computer remote monitoring
|
computer remote monitoring
|
|
|
|
|
|
touch screen control
|
touch screen control
|
touch screen control
|
touch screen control
|
touch screen control
|
|
|
|
|
|
report printing
|
report printing
|
report printing
|
report printing
|
report printing
|
◆ the company's product specifications are continuously developed and improved, and are subject to change without notice
◆ you can contact the company’s technical staff for inquiries and technical support
◆ for special specifications, please call the business department of the company, and the company accepts special customization for user needs